JG Wasseraufbereitung
600 GPD Membrane ULP-3213
600 GPD Membrane ULP-3213
SKU:20-8008
In stock
- Up to 2200 L / day
Couldn't load pickup availability
- Secure payment
- 14-day return policy
- 3 to 5 working days
600 GPD membrane ULP-3213 - osmosis filter
This ULP membrane can be operated with or without a booster pump and is suitable for the 600 GPD ULP Eco Power reverse osmosis system without electricity, and for the 600 GPD ULP with a booster pump. The 600 GPD ULP membrane is not suitable for regular systems, as this membrane is designed for lower water pressure. This ULP (Ultra Low Pressure) membrane achieves its full performance at just 4.5 bar. It also fits the 800 GPD ULP Eco Power reverse osmosis system. The Flow 1800 flow restrictor requires no modification.
Suitable for
- 600 GPD ULP Eco Power Reverse Osmosis System - without electricity
- 600 GPD ULP Brushless 1:1 with booster pump
Technical data
- 600 GPD high performance membrane ULP
- Model: QC-3213-600
- only fits in an 800 GPD membrane housing, model: 3213
- Pore size: 0.0001µm
- Retention rate: 95%
- Working temperature: +5°C to +38°C
- Dimensions: length 33.5cm x Ø 7.7cm
- latest dry membrane technology
- Quality membranes from Q-Icen®
Can also be used without electricity
- up to 2200 liters daily output¹, *possible from 4.5 bar water inlet pressure
- approx. 1.3-1.5 liters of pure water / minute, *at an optimal inlet pressure of 4.5 bar
- Water ratio: osmosis water / waste water: 1:1.5 (*from 4.5 bar water inlet pressure)
Information: If the water inlet pressure is low, the daily performance may decrease.
- up to 1646 litres daily output¹, *at approx. 3 bar water inlet pressure
- approx. 0.9 - 1.1 liters of pure water / minute *at approx. 3 bar water inlet pressure
- Water ratio: osmosis water / waste water: 1:2-3 (*approx. 3.0 bar water inlet pressure)
The higher the inlet pressure, the better the water ratio and the amount of pure water. At low water pressure, the maximum daily output will not be achieved.
Model // 600 GPD ULP membrane
Pressure in bar // Flow in GPD / Liter // Retention rate in %
1.0 ------- 150 / 567.81 ------- 90
1.5 ------- 228 / 863.07 ------- 92
2.0 ------- 307 / 1162.12 ------- 94
2.5 ------- 376 / 1423.31------- 95
3.0 ------ 435 / 1646.65 ------ 95
3.5 ------ 487 / 1843.49 ------- 95
4.0 ------ 567 / 2146.32 ------ 95
5.0 ------ 605 / 2290.17 ------ 95
- Usable water line pressure: from 3.5 - 6 bar. (Restricted use at low line pressure.)
- Optimal water pipe pressure: from 4.5 bar
- Rated power at 25°C water temperature
- Runtime: Suitable for continuous operation, 24/7 (only system without power)
- Recommended membrane change: every 24 months²
*at 25°C water temperature.
²depending on raw water quality and filter performance.
Removes virtually all harmful substances and flavors, such as viruses, bacteria, germs, hormones, lead, arsenic, pesticides, uranium, herbicides, fungicides, drug residues, limescale, and virtually all other contaminants. Only a TFC membrane can remove these contaminants.
storage
- Reverse osmosis membranes have a limited shelf life, approximately 6-12 months when stored at +5°C to +15°C.
- We recommend buying a new membrane immediately before changing the membrane or paying attention to the storage life!
Description
Description
Technical data
Technical data
Scope of delivery
Scope of delivery
Manufacturer information
Manufacturer information

